Evaluación térmica de tejas ecologicas en modelos físicos de galpones avicolas

Alves Damasceno, Flavio and Shiassi, Leonardo and Yanagi Junior, Tadayuki and Osorio Saraz, Jairo Alexander and De Oliveira, Jofran Luiz (2016) Evaluación térmica de tejas ecologicas en modelos físicos de galpones avicolas. DYNA, 83 (197). pp. 114-119. ISSN 2346-2183

Texto completo

[img]
Vista previa
PDF - Versión Publicada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

851kB

URL oficial: https://revistas.unal.edu.co/index.php/dyna/articl...

Resumen

En países con climas tropicales, como Brasil, las altas temperaturas asociadas con altas humedades relativas en el verano contribuyen como un factor de estrés en la producción animal. El calor excesivo dentro de una instalación avícola causa una reducción en el consumo de alimento y en la producción, y aumento en la mortalidad de las aves. Conociendo que el 75% de la carga de calor radiante dentro de una instalación viene desde el techo, es necesario estudiar alternativas que pueden minimizar esta radiación. El objetivo del presente trabajo fue analizar el ambiente térmico dentro de los modelos físicos de instalaciones de pollos de engorde construidos a escala reducida (1:10), donde el confort térmico se evaluó por el índice de humedad y de globo negro (BGHI) y la carga de calor radiante (RHL). Cinco modelos construidos fueron evaluados con diferentes materiales para techos. Basados en los resultados, se puede concluir que los techos construidos con tejas de cerámica (TB30), placas de fibra natural pintadas de blanco con en el lado externo (TFVP15) y placas de fabricadas con envases larga vida reciclado (TLV15), proporcionan los mejores ambientes térmicos., In countries with tropical climates, such as Brazil, the high summer temperatures associated with high relative humidities are a stress factor in animal production. Excessive heat within a poultry facility causes a reduction in feed intake and production, and increased bird mortality. With the knowledge that about 75% of the radiant heat load within a facility comes from the roof, it is necessary to study alternatives that can minimize this radiation. Thus, the objective of the present work is to analyze the thermal environment inside physical broiler housing models constructed on a reduced scale (1:10), where the thermal comfort was evaluated by the black globe humidity index (BGHI) and radiant heat load (RHL). Five models built with different roofing materials were evaluated. Based on the results, it can be concluded that roofs constructed with the channel clay roofing tile (TB30), natural fiber tiles with their external side painted white (TFVP15) and tiles made of recycled long-life packaging (TLV15), provide better thermal environments within the models.

Tipo de documento:Artículo - Article
Palabras clave:reduced models, thermal environment, alternative materials, thermal capacity, modelos a escala, ambiente térmico, materiales alternativos, capacidad térmica
Temática:6 Tecnología (ciencias aplicadas) / Technology > 62 Ingeniería y operaciones afines / Engineering
Unidad administrativa:Revistas electrónicas UN > Dyna
Código ID:58855
Enviado por : Dirección Nacional de Bibliotecas STECNICO
Enviado el día :31 Oct 2017 17:20
Ultima modificación:27 Noviembre 2017 22:04
Ultima modificación:27 Noviembre 2017 22:04
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Registry of Open Access Repositories OpenDOAR Metabiblioteca BDCOL OAIster Red de repositorios latinoamericanos DSpace BASE Open archives La referencia Colombiae Open Access Theses and Dissertations Tesis latinoamericanas CLACSO
Este sitio web se ve mejor en Firefox