Performance of a contact stabilization process for domestic wastewater treatment of cali, colombia

VÁSQUEZ SARRIA, NANCY and RODRÍGUEZ VICTORIA, JENNY and TORRES LOZADA, PATRICIA and MADERA PARRA, CARLOS (2011) Performance of a contact stabilization process for domestic wastewater treatment of cali, colombia. Dyna; Vol. 78, núm. 168 (2011); 98-107 DYNA; Vol. 78, núm. 168 (2011); 98-107 2346-2183 0012-7353 .

Texto completo

[img]
Vista previa
PDF
575kB
[img] HTML
45kB

URL oficial: http://revistas.unal.edu.co/index.php/dyna/article...

Resumen

The contact stabilization process has been applied in full-scale plants which treat domestic wastewater. The main advantage of this process is the short hydraulic retention time (HRT) in the contact reactor (CR), allowing treatment volumes significantly lower than in conventional activated sludge processes. This paper presents an analysis of the influence of the HRT and sludge recycle rate (r), on the performance of a contact stabilization process to remove organic matter and solids from the domestic wastewater of the city of Cali (Colombia). The research was carried out at Cañaveralejo Wastewater Treatment Plant (C-WWTP) facilities. The contact stabilization process was assessed at a pilot-scale unit treating raw wastewater influent to the C-WWTP. The HRT varied between 0.84 to 1.66 h in the contact reactor and 2.56 to 4.65 h in the stabilization reactor (SR). The evaluation of HRT was carried out with different r varying between 40 and 100%. The operational conditions that allowed for us to obtain the best performance in terms of organic load removal (14.05 kgCOD.d¯¹), with removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD₅), and total suspended solids (TSS) of 86, 87, and 82 %, respectively, were an HRT of 0.84 h in CR, and 4.11 h in SR, with a sludge recycle rate of 40%. In order to guarantee this performance, average values of sludge retention time (SRT) of 6 d; a volumetric organic load (VOL) of 2.13 kgBOD₅.(mᶾ.d) ¯¹; a food microorganism relation (F/M) of 0.89 kgBOD₅.(kgVSS.d)¯¹; and a mixed liquor volatile suspended solids (MLVSS) of 1125 mg.L¯¹ in CR, and 3173 mg.L¯¹ in SR, must be maintained.

Tipo de documento:Artículo - Article
Información adicional:Derechos de autor reservados
Palabras clave:Activated sludge, contact stabilization, organic matter removal, secondary wastewater treatment
Unidad administrativa:Revistas electrónicas UN > Dyna
Código ID:28082
Enviado por : Dirección Nacional de Bibliotecas STECNICO
Enviado el día :27 Junio 2014 19:16
Ultima modificación:18 Agosto 2014 18:14
Ultima modificación:18 Agosto 2014 18:14
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Registry of Open Access Repositories OpenDOAR Metabiblioteca BDCOL OAIster Red de repositorios latinoamericanos DSpace BASE Open archives La referencia Colombiae Open Access Theses and Dissertations Tesis latinoamericanas CLACSO
Este sitio web se ve mejor en Firefox