Escudo de la República de Colombia
Sistema Nacional de Biliotecas - Repositorio Institucional Universidad Nacional de Colombia Biblioteca Digital - Repositorio Institucional UN Sistema Nacional de Bibliotecas UN

Estudio dosimétrico de márgenes internos, a través de simulación de tratamiento de blancos bajo movimiento respiratorio / Dosimetric study of internal margins, through simulation of treatment of targets under respiratory movement

Martínez Téllez, Robinson (2009) Estudio dosimétrico de márgenes internos, a través de simulación de tratamiento de blancos bajo movimiento respiratorio / Dosimetric study of internal margins, through simulation of treatment of targets under respiratory movement. Maestría thesis, Universidad Nacional de Colombia.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

1MB

Resumen

Cuando se realizan tratamientos de radioterapia en zonas del cuerpo bajo la influencia del movimiento respiratorio, es necesario añadir un margen al volumen blanco clínico (CTV) para tener en cuenta los desplazamientos que este pudiera tener. En general, el margen adicionado, permite que el CTV se encuentre en todo momento dentro del haz de radiación, de tal forma que en algunos momentos del ciclo respiratorio será irradiada una gran cantidad de tejido normal. En este trabajo, se demuestra a través de simulaciones en un sistema de planeación, que con márgenes adecuados parte CTV podría estar fuera del haz de radiación en algunos instantes y aun así, tener una cobertura dosimétrica adecuada que no afecte el control tumoral pero que si proteja mayor cantidad de tejido normal. / Abstract. When treatments of radiotherapy are realized in zones of the body under the influence of the respiratory movement, is necessary to add a margin to the clinical target volume (CTV) to take into account the displacements that this may have. In general, the added margin, allows that the CTV is at all times within the beam of radiation, in such a way that in some moments of the respiratory cycle will be radiated a great quantity of normal tissue. In this work, there is demonstrated through simulations in a planning system, that with suitable margins part of the CTV could be out of the beam of radiation in some moments and yet, have adequate dosimetric coverage without compromising the tumor control but if protect more normal tissue.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Machado, Norman Harold
Información adicional:Magister en física médica
Palabras clave:Radiotherapy; Respiratory motion; Internal margin; Radioterapia; Movimiento respiratorio; Margen interno
Temática:5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Ciencias > Departamento de Física
Código ID:2742
Enviado por : Universidad Nacional de Colombia Biblioteca Digital - Sede Bogotá
Enviado el día :10 Enero 2011 14:53
Ultima modificación:09 Febrero 2011 22:16
Ultima modificación:09 Febrero 2011 22:16
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Registry of Open Access Repositories OpenDOAR Metabiblioteca BDCOL OAIster Red de repositorios latinoamericanos DSpace BASE Open archives La referencia Colombiae Open Access Theses and Dissertations Tesis latinoamericanas CLACSO
Este sitio web se ve mejor en Firefox