Implementación de un sistema de radiografía computarizada para verificación de tratamientos de radioterapia de intensidad modulada / Implementation of a computed radiography system for intensity modulated radiotherapy treatments verification

Giraldo Palacio, John Freddy (2010) Implementación de un sistema de radiografía computarizada para verificación de tratamientos de radioterapia de intensidad modulada / Implementation of a computed radiography system for intensity modulated radiotherapy treatments verification. Maestría thesis, Universidad Nacional de Colombia.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

2MB

Resumen

Se evalúa la implementación de un sistema de radiografía computarizada basado en placas de fósforo foto estimulables para la verificación de tratamientos de radioterapia de intensidad modulada. Se estudia el rango dinámico del sistema, la dependencia con la tasa de dosis y se realiza la calibración en dosis absorbida del sistema. A partir de la calibración en dosis, se realiza la verificación dosimétrica de campos cuadrados, midiendo la dosis, el tamaño del campo, la planicidad, la simetría y la penumbra. Se emplea el sistema de radiografía computarizada para la comprobación dosimétrica de tratamientos de imrt, usando como herramienta de análisis de acuerdo el índice gamma y el índice chi, aplicados sobre tres planes dosimétricos: uno de cabeza y cuello, otro de cérvix uterino y otro de próstata. Se concluye que el sistema de radiografía computarizada es una herramienta viable para fines de dosimetría y control de calidad en radioterapia. / Abstract. The implementation of a computed radiography photo-stimulated phosphor based system in the verification of imrt treatments is evaluated. The dynamic range and dose rate dependence are determined, and absorbed dose calibration is performed. Based on this calibration, square fields dosimetry is performed, measuring the absorbed dose, field size, flatness, symetry and penumbra. The computed radiography system is used for the dosimetric verification of imrt treatments, using gamma index and chi index as accordance criteria. Three treatment plans are analyzed: one for head and neck, one for uterine cervix and one for prostate. it’s concluded that cr system is a feasible tool for dosimetry of square fields and imrt inhomogenous treatments.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Mejía Montenegro, Alfonso
Información adicional:Magister en física médica
Palabras clave:Imrt; Radiografía computarizada; Control de calidad; Índice gamma; Computed radiography; Quality assurance; Gamma index
Temática:5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Ciencias > Departamento de Física
Código ID:2701
Enviado por : Universidad Nacional de Colombia Biblioteca Digital - Sede Bogotá
Enviado el día :05 Enero 2011 13:30
Ultima modificación:09 Febrero 2011 22:15
Ultima modificación:09 Febrero 2011 22:15
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Registry of Open Access Repositories OpenDOAR Metabiblioteca BDCOL OAIster Red de repositorios latinoamericanos DSpace BASE Open archives La referencia Colombiae Open Access Theses and Dissertations Tesis latinoamericanas CLACSO
Este sitio web se ve mejor en Firefox