Escudo de la República de Colombia
Sistema Nacional de Biliotecas - Repositorio Institucional Universidad Nacional de Colombia Biblioteca Digital - Repositorio Institucional UN Sistema Nacional de Bibliotecas UN

Análisis dosimétrico de las distribuciones de dosis para las técnicas de tratamiento (campos tangenciales con cuñas, campos complementarios e IMRT) en radioterapia de cáncer de mama

Mejía Agudelo, Luis Alfonso (2012) Análisis dosimétrico de las distribuciones de dosis para las técnicas de tratamiento (campos tangenciales con cuñas, campos complementarios e IMRT) en radioterapia de cáncer de mama. Maestría thesis, Universidad Nacional de Colombia.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

2MB

Resumen

El siguiente trabajo presenta una comparación entre tres técnicas de tratamiento en cáncer de mama: campos tangenciales con cuña, campos complementarios (Field in Field) y Radioterapia de Intensidad Modulada (IMRT). La comparación de estas técnicas se realizó mediante la evaluación de los histogramas dosis-volumen (DVH), que se obtienen en la realización de los planes de tratamiento en el sistema de planeación ECLIPSE 8.1, usando los siguientes parámetros de comparación: índice de conformación (CI), índice de homogeneidad (HI) y las restricciones de dosis de órganos a riesgo. Para esta comparación se escogieron 30 Tomografías Axiales Computarizadas, 15 de mama derecha y 15 de mama izquierda que además cumplieran con el hecho de ser volúmenes delimitados de un cáncer en estadío temprano. Como resultado se obtuvo que la técnica de campos complementarios dio un mejor cubrimiento al volumen blanco (mama) con relación a las otras dos técnicas: campos tangenciales con cuña e IMRT. A pesar que con la técnica IMRT el índice de homogeneidad obtenido fue mejor y la dosis en órganos a riesgo fue menor que en las otras dos técnicas, el índice de conformación fue más deficiente. Como conclusión se obtuvo que a pesar que la técnica IMRT tiene mejor índice de homogeneidad(HI) y su dosis a órganos a riesgo es menor, la técnica de campos complementarios (FIF) tiene un mejor índice de conformación (CI) y al realizar la evaluación de otros factores adicionales (como el tiempo de entrega del tratamiento sobre el paciente, el control de calidad que se debe realizar al tratamiento en IMRT, etc) se sugiere utilizar para el caso particular aquí analizado la técnica FIF ., Abstract. This work presents a comparison among three techniques in breast cancer treatment: wedged tangential fields (WTF), Field in Field (FIF) and IMRT. The comparison of these techniques is performed by evaluating the dose-volume histograms (DVH), which are obtained in carrying out plans in the treatment planning system ECLIPSE 8.1, using the following comparison parameters: conformation index (CI), homogeneity index (HI) and dose constraints to organs at risk. For this comparison we chose 30 CT scans, 15 right breast and 15 left breast which an early-stage cancer. The result was that the technique of complementary fields gave better coverage to target volume (breast) relative to the other two techniques: wedge tangential fields and IMRT. The homogeneity index and dose to organs at risk was better in IMRT that although the other two techniques. In conclusion we drew that despite the IMRT technique has better HI and dose to organs at risk is lower, the best performing technique in balance is the complementary field since being 3DCRT technique with direct planning your time implementation of a patient is less than the IMRT technique.

Tipo de documento:Tesis/trabajos de grado - Thesis (Maestría)
Colaborador / Asesor:Plazas de Pinzón, María Cristina
Información adicional:Magister en Física Médica. Línea de Investigación: Radioterapia
Palabras clave:Histogramas dosis-volumen (DVH), Índice de conformación (CI), Índice de homogeneidad (HI), Dosis órganos a riesgo, Campos tangenciales con cuña (CTC), Campos complementarios (FIF) e IMRT.), Dose-volume histograms (DVH), Conformation index (CI), Homogeneity index (HI), Dose to organs at risk, Wedged tangential fields (WTF), Field in field (FIF) and IMRT
Temática:5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Ciencias > Departamento de Física
Código ID:12966
Enviado por : Universidad Nacional de Colombia Biblioteca Digital -3- Sede Bogotá
Enviado el día :20 Junio 2014 14:28
Ultima modificación:20 Junio 2014 14:28
Ultima modificación:20 Junio 2014 14:28
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Registry of Open Access Repositories OpenDOAR Metabiblioteca BDCOL OAIster Red de repositorios latinoamericanos DSpace BASE Open archives La referencia Colombiae Open Access Theses and Dissertations Tesis latinoamericanas CLACSO
Este sitio web se ve mejor en Firefox