Valores de referencia de electromiografia de fibra única con electrodo de aguja concéntrica y estímulo de superficie en músculo orbicularis oculi en población adulta joven

Rodríguez Lozano, Ana Milena (2012) Valores de referencia de electromiografia de fibra única con electrodo de aguja concéntrica y estímulo de superficie en músculo orbicularis oculi en población adulta joven. Otra thesis, Universidad Nacional de Colombia.

Texto completo

[img]
Vista previa
PDF - Versión Aceptada
Available under License Creative Commons Attribution Non-commercial No Derivatives.

406kB

Resumen

Objetivo: Estimar los valores de referencia para el jitter en el músculo orbicularis oculi mediante estímulo de superficie y registro con electrodo de aguja concéntrica. Materiales y Métodos: Un electrodo de barra bipolar se ubicó en la mitad de la distancia entre el trago y el ángulo externo del ojo. Se realizó el estímulo con duración de 0.05ms, a una rata de 10Hz y máxima intensidad de 10mA. Los filtros se ajustaron a 2khz y 10khz para paso alto y bajo respectivamente, y se registró el potencial de una fibra muscular con aguja concéntrica insertada vía subcutánea en la porción orbitaria del músculo orbicularis oculi. Resultados: El examen fue realizado en 53 sujetos normales (25 hombres y 28 mujeres con edad media de 30,5años). El jitter fue expresado como la media de la diferencia consecutiva (MCD) de 10 potenciales individuales. La media MCD fue de 14,5μs +/- 2,8 (límite superior 95% 21μs) promedio mínimo 8,5μs y promedio máximo 22μs. La media MCD de todos los potenciales (n=530) fue de 15,4μs +/- 5,4 (límite superior 95%: 27μs) valor mínimo 5,0μs y valor máximo 31,4μs. El tiempo promedio de duración de la prueba fue de 18 minutos y el puntaje promedio de la Escala Visual Análoga fue de 2. Conclusiones: La realización de la EMG de fibra única mediante estímulo de superficie y electrodo de aguja concéntrica es una prueba fácil, accesible, de corta duración y poco dolorosa; óptima para individuos con alteración del estado de conciencia y población pediátrica. Los resultados obtenidos pueden servir como referencia para el diagnóstico de enfermedad de la placa neuromuscular utilizando un método práctico y seguro., Abstract. Objectives: To estimate the reference values for the jitter in the orbicularis oculi (OOc) through surface stimulus and recording with a concentric needle electrode (CNE). Methods: A bipolar rod electrode was placed midway between the tragus and the external angle of the eye. Stimulation was conducted for 0.05 ms at 10 Hz and a maximum intensity of 10 mA. The filters were adjusted to settings of 2 kHz and 10 kHz for the low-cut and high-pass filters, respectively, and the potential of one muscle fiber was recorded with a CNE inserted subcutaneously in the orbital portion of the OOc. Results: The test was performed on 53 normal control subjects (25 men, 28 women; mean age, 30.5 years). The jitter was expressed as the mean of the consecutive difference (MCD) of 10 individual potentials. The MCD was 14.5 ± 2.8 s (upper 95% limit: 21 s, minimum average: 8.5 s, maximum average: 22 s). The MCD for all of potentials (n=530) was 15.4 ± 5.4 s(upper 95% limit: 27 s, minimum value: 5.0 s, maximum value: 31.4 s). The average time was 18 minutes and the average score on the visual analogue scale was 2. Conclusions: The realization of single fiber electromyography by means of surface stimulation and a CNE is an easy test to perform, affordable, quickly completed, and not very painful. It is ideal for people with an altered state of consciousness and the pediatric population. These results could serve as a reference to diagnose diseases of the neuromuscular plate using a practical and safe method.

Tipo de documento:Tesis/trabajos de grado - Thesis (Otra)
Colaborador / Asesor:Ortiz Corredor, Fernando
Información adicional:Especialista en Medicina Física y Rehabilitación. Línea de Investigación: Electrodiagnóstico
Palabras clave:Electromiografia de fibra única, Electrodo de aguja concéntrica, Estímulo de superficie, Jitter, Valores de referencia, Single fiber electromyography, Concentric needle electrode, Surface stimulation, Reference values
Temática:5 Ciencias naturales y matemáticas / Science > 53 Física / Physics
6 Tecnología (ciencias aplicadas) / Technology > 61 Ciencias médicas; Medicina / Medicine & health
Unidad administrativa:Sede Bogotá > Facultad de Medicina > Departamento de Medicina Física y Rehabilitacion
Código ID:11128
Enviado por : Universidad Nacional de Colombia Biblioteca Digital -2-Sede Bogotá
Enviado el día :15 May 2014 16:32
Ultima modificación:15 May 2014 16:32
Ultima modificación:15 May 2014 16:32
Exportar:Clic aquí
Estadísticas:Clic aquí
Compartir:

Solamente administradores del repositorio: página de control del ítem

Vicerrectoría de Investigación: Número uno en investigación
Indexado por:
Indexado por Scholar Google WorldCat DRIVER Registry of Open Access Repositories OpenDOAR Metabiblioteca BDCOL OAIster Red de repositorios latinoamericanos DSpace BASE Open archives La referencia Colombiae Open Access Theses and Dissertations Tesis latinoamericanas CLACSO
Este sitio web se ve mejor en Firefox